This manual provides an overview of the BITMAIN Antminer L7, demonstrates how to set up, configure, monitor, and administer the server, and also introduces the necessary environmental conditions.
1. BITMAIN Antminer L7 Overview
The Bitmain Antminer L7 server is Bitmain’s newest version in the current series. Power supply APW121417 is part of L7 server. All L7 servers are tested and configured prior to shipping to ensure easy set up.
Caution:
- Please refer to the layout above to place your goods in usage in case of any damage.
- The equipment must be connected to an earthed mains socket-outlet. The socket-outlet shall be installed near the equipment and shall be easily accessible.
- The equipment has two power inputs, only by connecting those two power supply sockets simultaneously can the equipment run. When the equipment is powered off, be sure to power off all power inputs.
- DO NOT remove any screws and cables tied on the product.
- DO NOT PRESS the metal button on the cover.
- Please note that the actual server shall prevail.
1.1 L7 Server Components
The main components and controller front panel of L7 miners are shown in the following figure:
APW121417 Power Supply:
Note:
- Power supply APW121417 is part of L7 server. For detailed parameters, please refer to the specifications below.
- Additional two power cords are needed.
1.2 Specifications
- Version: L7
- Model No.: 240-L
Product Glance | Value |
Version | L7 |
Model | 240-L |
Crypto Algorithm/Coins | Scrypt |
Hashrate, MH/s | 9500 ± 3% |
power on wall@25℃, Watt | 3420 ± 10% |
power efficiency on wall @25°C, J/MH | 0.36 ± 10% |
Detailed Characteristics | Value |
Power Supply | |
Power supply AC input voltage, Volt (1-1) | 200~240 |
Power supply AC Input Frequency Range, Hz | 47~63 |
Power supply AC Input current, Amp(1-2) | 20(1-3) |
Hardware Configuration | |
Network connection mode | RJ45 Ethernet 10/100M |
Server Size (Length*Width*Height, w/o package), mm(2-1) | 370*195.5*290 |
Server Size (Length*Width*Height, with package), mm | 570*316*430 |
Net weight, kg (2-2) | 13.5 |
Gross weight, kg | 15.0 |
Environment Requirements | |
Operation temperature, °C | 0~40 |
Storage temperature, °C | –20~70 |
Operation humidity(non-condensing), RH | 10~90% |
Operation altitude, m(3-1) | ≤2000 |
Power Supply
Detailed Characteristics | Value |
Power supply AC input voltage, Volt (1-1) | 200~240 |
Power supply AC Input Frequency Range, Hz | 47~63 |
Power supply AC Input current, Amp(1-2) | 20(1-3) |
Hardware Configuration
Detailed Characteristics | Value |
Network connection mode | RJ45 Ethernet 10/100M |
Miner Size (Length*Width*Height, w/o package), mm(2-1) | 370*195.5*290 |
Miner Size (Length*Width*Height, with package), mm | 570*316*430 |
Net weight, kg (2-2) | 13.5 |
Gross weight, kg | 15 |
Environment Requirements
Detailed Characteristics | Value |
Operation temperature, °C | 0~40 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10~90% |
Operation altitude, m(3-1) | ≤2000 |
Notes:
- Caution: Wrong input voltage may probably cause server damaged
- Max condition: temperature 40°C, altitude 0m
- Two AC input wires, 10A per wire
- Including PSU sizeIncluding PSU weight
When the server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃ for every increase of 300m
2. Setting up the BITMAIN Antminer L7 Server
To set up the server:
Note:
The file IPReporter.zip is supported by Microsoft Windows only.
1. Download the following file: IPReporter.zip.
2. Extract the file.
Note:
The default DHCP network protocol distributes IP addresses automatically.
3. Right-click IPReporter.exe and run it as Administrator.
4. Select one of the following options:
Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
Default – suitable for home servers.
5. Click Start.
The IP address will be displayed in a window on your computer screen.
6. In your web browser, enter the IP address provided.
7. Proceed to login using root for both the username and password.
8. In the Protocol section, you can assign a Static IP address (optional).
9. Enter the IP address, Subnet mask, gateway and DNS Server.
10. Click “Save”.
3. Configuring the BITMAIN Antminer L7 Server
Setting up the Pool
Best Mining Pools for Bitmain Antminer L7
To configure the server:
1. Click Settings marked below.
Note:
Fan speed percentage can be adjusted, but we recommend to keep the default setting. The server will adjust the fan speed automatically if the fan speed percentage has yet been selected.
2. Set the options according to the following table:
Option | Description |
Mining address | Enter the address of your desired pool. Note: The L7 servers can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3). The pools with low priority will only be used if all higher priority pools are offline. |
Name | Your worker ID on the selected pool. |
Password (optional) | The password for your selected worker. |
3. Click Save after the configuration.
4. Monitoring BITMAIN Antminer L7 Server
To check the operating status of your server:
1. Click dashboard marked below to check the server status (taking L7 9500T as an example).
Note: The L7 server (9500T) is with fixed frequency 1850 MHz. Firmware will stop running when the Temp (Outlet) reaches to 80℃,there will be an error message “over max temp, pcb temp (real-time temp)” shown on the bottom of kernel log page. Meanwhile, the server temperature on the dashboard interface turns to abnormal and shows “Temp is too high”.
2. Monitor your server according to the descriptions in the following table:
Option | Description |
Number of chips | Number of chips detected in the chain. |
Frequency | ASIC frequency setting. |
Real Hashrate | Real-time Hashrate of each hash board (GH/s). |
Inlet Temp | Temperature of the inlet (°C). |
Outlet Temp | Temperature of the outlet (°C). |
Chip state | One of the following statuses will appear: ● The Green Icon – indicates normal● The Red Icon– indicates abnormal |
.
5. Administering BITMAIN Antminer L7 Server
5.1 Checking Your Firmware Version
To check your firmware version:
- Enter the backstage of your server, find the firmware version on the bottom.
- Firmware Version displays the date of the firmware your server uses. In the examples below, the server is using firmware version 20210701.
5.2 Upgrading Your System
Note:
Make sure that the L7 server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair.
Download the latest version firmware of Antminer L7.
To upgrade the server’s firmware:
1. In System, click Firmware Upgrade.
2. For Keep Settings:
- Select “keep settings” to keep your current settings (default).
- Unselect “keep settings” to reset the server to default settings.
3. When the upgrade is completed, restart the server and it will turn to the setting page.
5.3 Modifying Your Password
To change your login password:
- In System, click the Password tab.
- Set your new password, then click Save.
5.4 Restoring Initial Settings
To restore your initial settings
- Turn on the server and let it run for 5 minutes.
- On the controller front panel, press and hold the Reset button for 10 seconds.
Note:
Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.
6. BITMAIN Antminer L7 Environmental Requirements
Please run your server in accordance with the following requirements
6.1 Basic Environmental Requirements:
Climatic Conditions:
Description | Requirement |
Operating Temperature | 0-40℃ |
Operating Humidity | 10-90%RH (non-condensing) |
Storage Temperature | -20-70℃ |
Storage Humidity | 5-95%RH(non-condensing) |
Altitude | <2000m |
- Site Requirements of the Server Running Room:
Please keep the server running room away from industrial pollution sources:
For heavy pollution sources such as smelters and coal mines, the distance should be more than 5km.
For moderate pollution sources such as chemical industries, rubber and electroplating industries, the distance should be more than 3.7km.
For light pollution sources such as food factories and leather processing factories, the distance should be more than 2km.
If unavoidable, the site should be chosen in the perennial upwind direction of the pollution source.
Please do not set your location within 3.7km from the seaside or the salt lake. If unavoidable, it should be built as airtight as possible, equipped with air conditioning for cooling.
Electromagnetic Environmental Conditions:
Please keep your site away from transformers, high-voltage cables, transmission lines and high-current equipment, for example, there should be no high-power AC transformers (>10KA) within 20 meters, and no high-voltage power lines within 50 meters. Please keep your site away from high-power radio transmitters, for example, there should be no high-power radio transmitters (>1500W) within 100 meters.
Other Environmental Requirements:
The server running room shall be free of explosive, conductive, magnetically conductive and corrosive dust. The requirements of mechanical active substances are shown below:
Requirements of Mechanical Active Substances
Mechanical Active Substance | Requirement |
Sand | <= 30mg/m3 |
Dust (suspended) | <= 0.2mg/m3 |
Dust (deposited) | <=1.5mg/m2h |
Requirements of Corrosive Gas
Corrosive Gas | Unit | Concentration |
H2S | ppb | < 3 |
SO2 | ppb | < 10 |
Cl2 | ppb | < 1 |
NO2 | ppb | < 50 |
HF | ppb | < 1 |
NH3 | ppb | < 500 |
O3 | ppb | < 2 |
Note: ppb (part per billion) refers to the unit of concentration,1ppb stands for the volume ratio of part per billion.