1. BITMAIN Antminer L7 Overview

The Bitmain Antminer L7 server is Bitmain’s newest version in the current series. Power supply APW121417 is part of L7 server. All L7 servers are tested and configured prior to shipping to ensure easy set up.

L7 Server Installation Guide

Caution:

  1. Please refer to the layout above to place your goods in usage in case of any damage.
  2. The equipment must be connected to an earthed mains socket-outlet. The socket-outlet shall be installed near the equipment and shall be easily accessible.
  3. The equipment has two power inputs, only by connecting those two power supply sockets simultaneously can the equipment run. When the equipment is powered off, be sure to power off all power inputs.
  4. DO NOT remove any screws and cables tied on the product.
  5. DO NOT PRESS the metal button on the cover.
  6. Please note that the actual server shall prevail.

1.1 L7 Server Components

The main components and controller front panel of L7 miners are shown in the following figure:

L7 Server Installation Guide

APW121417 Power Supply:

L7 Server Installation Guide

Note:

  1. Power supply APW121417 is part of L7 server. For detailed parameters, please refer to the specifications below.
  2. Additional two power cords are needed.

1.2 Specifications

  • Version: L7
  • Model No.: 240-L
Product GlanceValue
VersionL7
Model240-L
Crypto Algorithm/CoinsScrypt
Hashrate, MH/s9500 ± 3%
power on wall@25℃, Watt3420 ± 10%
power efficiency on wall @25°CJ/MH0.36 ± 10%
 
Detailed CharacteristicsValue
Power Supply
Power supply AC input voltage, Volt (1-1)200~240
Power supply AC Input Frequency Range, Hz47~63
Power supply AC Input current, Amp(1-2)20(1-3)
Hardware Configuration
Network connection modeRJ45 Ethernet 10/100M
Server Size (Length*Width*Height, w/o package), mm(2-1)370*195.5*290
  Server Size (Length*Width*Height, with package), mm  570*316*430
Net weight, kg (2-2)13.5
Gross weight, kg15.0
Environment Requirements
Operation temperature, °C0~40
Storage temperature, °C–20~70
Operation humidity(non-condensing), RH10~90%
Operation altitude, m(3-1)≤2000

Power Supply

Detailed CharacteristicsValue
Power supply AC input voltage,  Volt (1-1)200~240
Power supply AC Input Frequency Range, Hz47~63
Power supply AC Input current, Amp(1-2)20(1-3)

Hardware Configuration

Detailed CharacteristicsValue
Network connection modeRJ45 Ethernet 10/100M
Miner Size (Length*Width*Height, w/o package), mm(2-1)370*195.5*290
Miner Size (Length*Width*Height, with package), mm570*316*430
Net weight, kg (2-2)13.5
Gross weight, kg15

Environment Requirements

Detailed CharacteristicsValue
Operation temperature, °C0~40
Storage temperature, °C-20~70
Operation humidity(non-condensing), RH10~90%
Operation altitude, m(3-1)≤2000

Notes:

  1. Caution: Wrong input voltage may probably cause server damaged
  2. Max condition: temperature 40°C, altitude 0m
  3. Two AC input wires, 10A per wire
    1. Including PSU sizeIncluding PSU weight

When the server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃ for every increase of 300m

2. Setting up the BITMAIN Antminer L7 Server

To set up the server:

Note:
The file IPReporter.zip is supported by Microsoft Windows only.

1. Download the following file: IPReporter.zip.

2. Extract the file.
Note: 
The default DHCP network protocol distributes IP addresses automatically.

3. Right-click IPReporter.exe and run it as Administrator.

4. Select one of the following options:

Shelf, Step, Position – suitable for farm servers to mark the location of the servers.

Default – suitable for home servers.

5. Click Start.

L7 Server Installation Guide
L7 Server Installation Guide

The IP address will be displayed in a window on your computer screen.

L7 Server Installation Guide

6. In your web browser, enter the IP address provided.

7. Proceed to login using root for both the username and password.

8. In the Protocol section, you can assign a Static IP address (optional).

9. Enter the IP address, Subnet mask, gateway and DNS Server.

10. Click “Save”.

L7 Server Installation Guide

3. Configuring the BITMAIN Antminer L7 Server

Setting up the Pool

Best Mining Pools for Bitmain Antminer L7

To configure the server:

1. Click Settings marked below.

BITMAIN Antminer L7 Server Installation

Note:
Fan speed percentage can be adjusted, but we recommend to keep the default setting. The server will adjust the fan speed automatically if the fan speed percentage has yet been selected.

2. Set the options according to the following table:

OptionDescription
Mining addressEnter the address of your desired pool.  Note: The L7 servers can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3). The pools with low priority will only be used if all higher priority pools are offline.
NameYour worker ID on the selected pool.
Password (optional)The password for your selected worker.

3. Click Save after the configuration.

4. Monitoring BITMAIN Antminer L7 Server

To check the operating status of your server:

1. Click dashboard marked below to check the server status (taking L7 9500T as an example).

L7 Server Installation Guide

Note: The L7 server (9500T) is with fixed frequency 1850 MHz. Firmware will stop running when the Temp (Outlet) reaches to 80℃,there will be an error message “over max temp, pcb temp (real-time temp)” shown on the bottom of kernel log page. Meanwhile, the server temperature on the dashboard interface turns to abnormal and shows “Temp is too high”.

2. Monitor your server according to the descriptions in the following table:

OptionDescription
Number of chipsNumber of chips detected in the chain.
FrequencyASIC frequency setting.
Real HashrateReal-time Hashrate of each hash board (GH/s).
Inlet TempTemperature of the inlet (°C).
Outlet TempTemperature of the outlet (°C).
Chip stateOne of the following statuses will appear:  ●       The Green Icon – indicates normal●       The Red Icon– indicates abnormal

.

5. Administering BITMAIN Antminer L7 Server

5.1 Checking Your Firmware Version

To check your firmware version:

  1. Enter the backstage of your server, find the firmware version on the bottom.
  2. Firmware Version displays the date of the firmware your server uses. In the examples below, the server is using firmware version 20210701.
L7 Server Installation Guide

5.2 Upgrading Your System

Note:

Make sure that the L7 server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair.

Download the latest version firmware of Antminer L7.

To upgrade the server’s firmware:

1. In System, click Firmware Upgrade.

L7 Server Installation Guide

2. For Keep Settings:

  • Select “keep settings” to keep your current settings (default).
  • Unselect “keep settings” to reset the server to default settings.

3. When the upgrade is completed, restart the server and it will turn to the setting page.

L7 Server Installation Guide

5.3 Modifying Your Password

To change your login password:

  1. In System, click the Password tab.
  2. Set your new password, then click Save.
L7 Server Installation Guide

5.4 Restoring Initial Settings

To restore your initial settings

  1. Turn on the server and let it run for 5 minutes.
  2. On the controller front panel, press and hold the Reset button for 10 seconds.

Note:

Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.

6. BITMAIN Antminer L7 Environmental Requirements

Please run your server in accordance with the following requirements

6.1 Basic Environmental Requirements:

Climatic Conditions:

DescriptionRequirement
Operating Temperature0-40℃
Operating Humidity10-90%RH (non-condensing)
Storage Temperature-20-70℃
Storage Humidity5-95%RH(non-condensing)
Altitude<2000m

  • Site Requirements of the Server Running Room:
    Please keep the server running room away from industrial pollution sources:
    For heavy pollution sources such as smelters and coal mines, the distance should be more than 5km.
    For moderate pollution sources such as chemical industries, rubber and electroplating industries, the distance should be more than 3.7km.
    For light pollution sources such as food factories and leather processing factories, the distance should be more than 2km.
    If unavoidable, the site should be chosen in the perennial upwind direction of the pollution source.
    Please do not set your location within 3.7km from the seaside or the salt lake. If unavoidable, it should be built as airtight as possible, equipped with air conditioning for cooling.

Electromagnetic Environmental Conditions:
Please keep your site away from transformers, high-voltage cables, transmission lines and high-current equipment, for example, there should be no high-power AC transformers (>10KA) within 20 meters, and no high-voltage power lines within 50 meters. Please keep your site away from high-power radio transmitters, for example, there should be no high-power radio transmitters (>1500W) within 100 meters.

Other Environmental Requirements:

The server running room shall be free of explosive, conductive, magnetically conductive and corrosive dust. The requirements of mechanical active substances are shown below:

Requirements of Mechanical Active Substances

Mechanical Active SubstanceRequirement
Sand<= 30mg/m3
Dust (suspended)<= 0.2mg/m3
Dust (deposited)<=1.5mg/m2h

Requirements of Corrosive Gas

Corrosive GasUnitConcentration
H2Sppb< 3
SO2ppb< 10
Cl2ppb< 1
NO2ppb< 50
HFppb< 1
NH3ppb< 500
O3ppb< 2

Note: ppb (part per billion) refers to the unit of concentration,1ppb stands for the volume ratio of part per billion.